SS2350 SA
Sapphire Hybrid Permanent Downhole Gauge, Standard Service
Product Description
BlueFin’s Standard Service Sapphire Permanent Downhole Gauge (PDG) has been designed to provide high-resolution pressure and temperature data in the hostile downhole oil and gas well environment.
The SS2350 series PDG electronics utilize hybrid electronic packaging technology to minimize electronic aging and ensure long-term reliability. Proprietary signal processing techniques are used to maximize accuracy, stability, and resolution. The electronics and sensors are packaged in a pressure vessel made of 17-4 PH stainless steel (3). The system is filled with an inert material and fully welded (no elastomers).
Benefits & Applications
Applications include permanent monitoring, drill stem testing, hydraulic fracturing, chemical treatments, reservoir characterization
100% welded gauge design with testable metal-to-metal seal cable head (Choice of single or dual redundant M2M seals available)
Testable Metal-to-Metal seal between Gauge and Gauge Mandrel
Hybrid Electronics for long term reliability to 150°C
RTD sensor - high accuracy and resolution temperature measurement
Capable of either Annular or Tubing measurement
Sample Rate: From 1 sample per sec up to 1 sample per 24 hrs
Length: 20.4” (OAL), 19.5” (Make up Length)
General Specifications
Calibrated Pressure Range: 10k, 15k psi
Diameter: 0.75”
Material: 3 17-4 PH DH1150
TEC Configuration: 1/8” or 1/4” TEC
Temperature Specifications
Operating Temp Range: 25°C to 150°C (77°F to 302°F)
Maximum Temp (1): 170°C (338°F)
Temperature Accuracy (2): +/-0.5°C (Standard), +/- 0.1°C (Enhanced)
Temperature Resolution: < 0.001°C
Temperature Drift: < 0.1°C
Pressure Specifications
Pressure Accuracy: 0.030% Full Scale
Pressure Resolution: 0.0003% Full
Scale Drift: < 0.03% Full Scale/year
Notes:
The long-term operating temperature for this gauge is 150°C, however, it can be exposed temporarily up to 170°C. e.g. during well treatment operations.
The standard calibration temperature accuracy is +/- 0.5°C. Where required an enhanced calibration is available on a build to order basis; this increases the temperature accuracy to +/-0.1°C
BlueFin’s Standard Service Sapphire Gauge is manufactured from 17-4 PH DH1150 material. NACE rating restricted MR0175. This allows the use of 17-4 PH in some mild sour applications. For harsher environments, our Sour Service Sapphire Gauge, manufactured from Inconel®-718, is recommended.